Part No. 10-02010
SUPER-Z Head-Stage
Very high-impedance head-stage for use with all CWE amplifiers, including BMA-200, BMA-400, and BMA-931. Features switchable 1X/10X gain, AC or DC coupling, DC microvolt calibrator, and adjustable DC offset. Inputs are 0.080″ (2mm) pin jacks. Flip-up feet (shown extended).
Dimensions: 3.5″W x 4″D x 1″H (8.9 x 10.1 x 2.5cm)
Part No. 10-02020
ISO-Z Head-Stage
Electrically isolated head-stage for use with all CWE amplifiers, including BMA-200, BMA-400, and BMA-931. Features 10X gain, DC coupling, 500uV AC calibrator. Inputs are 1.5mm Touch-Proof sockets. Flip-up feet (shown extended)
Dimensions: 3.5″W x 4″D x 1″H (8.9 x 10.1 x 2.5cm)
Part No. 10-02063
E-422 Snap-type electrode leads, set of 3
Color-coded standard snap leads for disposable ECG-type electrodes. 39″ (1m) long, terminated with 1.5mm Touch-Proof plug. Does not include electrodes.
Part No. 10-02065
Alligator clip electrode leads, set of 3
Color-coded, solid copper miniature alligator clip leads. 39″ (1m) long, terminated with 1.5mm Touch-Proof plug. Application: animal ECG recording.
Part No. 10-02064
NEE-3 Needle electrode leads, set of 3
Small diameter stainless steel electrode leads. 39″ (1m) long, terminated with 1.5mm Touch-Proof plug. Application: animal ECG or EMG recording.
Part No. 10-02060
E-220X-LS reusable Ag-AgCl electrode leads, each
1cm overall diameter biopotential skin electrode, 39″ (1m) long, terminated with 1.5mm Touch-Proof plug. Application: ECG or surface EMG recording. Requires Adhesive Disks and electrode gel (see below)
Part No. 10-02062
E-401 Adhesive Disks for E-220X-LS electrodes, pack of 100
Self-adhesive washers for attaching reusable electrodes.
Part No. 10-02051
PIN-DIN Adapter wire, set of 3
Use for adapting pin-plug terminated leads to 1.5mm Touch-Proof sockets. 5″ (12cm) long.
Part No. 10-02040
BMA-931/CON 7-pin amplifier input plug, each
Unwired input connector for BMA-200, BMA-400, BMA-931, CT-1000. Use this plug for making custom input cables.
Part No. 10-04020
PM-CON 6-pin transducer amplifier input plug, each
Unwired input connector for BP-100, TA-100, BP-832. Use this plug for making custom transducer input cables.
Part No. 10-02050
PIN-PLUGS, set of 3
Unwired pin plugs, 0.080″ (2mm) dia., color-coded set of three. Use for wiring custom electrode leads.
Xperiment Girl’s past was shrouded in mystery until now. Xperiment Girl was originally the international respected Dr. Gene Knockout researcher extraordinaire, a living legend working out of her hidden Nerve Center at IITC. For most of her career, Xperiment Girl worked with inferior equipment resulting in bad data.
Teaching the fine art of mastering and measuring accurately tail cuff blood pressure on mice, rats and all other animals, Xperiment Girl in turn intrigued by pain and how she could assist in superior equipment in the field of pain tolerance, fascination/became obsessed with solving poor test data from inferior equipment. Continue reading...