Continuous Infusion Syringe Pump System

Features

Description

Eliminates Flow Rate Pauses & Drop-Offs

The DUAL-NE-1000X Continuous Pump System eliminates the problem of flow rate drop-offs and pauses found in Push-Pull syringe pump systems. With Push-Pull systems, one syringe infuses, while the other refills, then they switch directions. This switch of directions causes a delay in flow while the syringes are primed.The DUAL-NE1000X Continuous Pump System solves the inconsistent flow rate problems of push-pull pumps.

How it works:

The refilling syringe pump fills the syringe at a faster rate than the infusing syringe pump infuses, giving it time to prime the syringe after the syringe is filled, or even overlap the infusion to create a seamless transition between syringes.

The smoothness of the transition between syringes can be fine tuned by adjusting the infusion rate, refill rate, priming rate, prime volume and overlap volume parameters.

Description:

Requirement:

Two Pumps from the NE-1000X family of syringe pumps (any 2 NE-1000 family of syringe pumps with an X upgrade in each pump). Pumps can be different models. One dual pump cable (Model: CBL-DUAL-3).

Features of the DUAL-NE-1000X:

  • Includes: 2 NE-1000X programmable single syringe pumps, sync cable kit and two power supplies.
  • Utilizes specialized dual pump sync cable kit to synchronize both pumps.
  • Flexibility for the pumps to perform either continuous flow, emulsification or independently at any time.

Features of the NE-1000X Family of Syringe Pumps:

  • Built for automation
  • Operates stand-alone or from a computer
  • Infusion and withdrawal
  • Set a single pumping rate and/or dispensing volume
  • Applications range from simple infusions to complex pumping programs
  • Programmable preset protocols
  • Program up to 41 pumping phases that change pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound the buzzer
  • RS-232 and TTL logic control interfaces
  • Network, control, and monitor up to 100 pumps with one computer.
  • Gradient ramping of flow rates
  • Worldwide power supplies available
  • Motor stall detection
  • Non-volatile memory of all parameters and programming
  • Upgradable to 340 pumping phases program memory with the X2 Upgrade
  • Dispensing accuracy of +/-1%
  • Unlimited lifetime technical support
  • Two year warranty

Example Flow Rates for the DUAL-NE-1000X:

Syringe Size Maximum Rate Minimum Rate
0.5µL 25.49 µL/hr 0.001 µL/hr
1 mL 53.09 mL/hr 0.73 µL/hr
3 mL 192.5 mL/hr 2.646 µL/hr
5 mL 406.1 mL/hr 5.581 µL/hr
10 mL 600 mL/hr 8.244 µL/hr
20 mL 975.8 mL/hr 13.41 µL/hr
30 mL 1282 mL/hr 17.63 µL/hr
60 mL 2120 mL/hr 29.13 µL/hr


Dual Pump Plumbing Kit

Description:

  • For use with our continuous infusion system or dual infusion system
  • Provides a dual check valve for two syringes, withdraw will pull fluid from a reservoir and infusion will output into a separate line
  • The kit is pre-assembled, all you need to do is plug in the syringes
  • Each dual check valve uses 6″ of 1/8″ tubing to connect to a Y connector, one for reservior and one for output; each Y-connector has 5′ of tubing to make connections to your application. Two 60cc Terumo syringes are included
  • Individual parts are also available

Specs

Articles

Software