Type
T Thermocouple Probes |
|
|
|
Needle Microprobes |
|
Type |
Dia. |
Time
Constant |
| MT-23 |
23 ga. (.125") |
.15 secs. |
| MT-26 |
26 ga. (.018") |
.1 secs. |
| MT-29 |
29 ga. (.013") |
.125 secs. |
|
| |
Fast-response
needle probes for instant readings in tissue, semisolids, liquids.
Also for very small specimens, powders and materials. Needle tip is
sealed to ensure only stainless steel contacts specimen. Max. temp.
200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short
probes are easier to insert and last longer. Type #'s indicate needle
gauge and needle length in cm..-
Sizes Available (ga/cm.):
MT-29/1, MT-29/2, MT-29/3, MT-29/5
MT-26/2, MT-26/4, MT-26/6
MT-23/3, MT-23/5, MT-23/8
MT-4 - Similar to MT-29/1
but has blunt tip. Good for instant skin and surface temperatures,
liquids. Time constant .025 secs. Not isolated.
ICT-4 - For use on integrated circuits and other micro
specimens. 0.013" dia. straight stainless steel shaft; slightly
protruding sensor bead to facilitate temperature probing. 5" tubular
handle fits micro- manipulators. Max. Intermittent Temp. 200°C,
continuous use 100°C, Time constant 0.25 secs. 5 ft. lead. Not
Isolated.
MT-29/1B - Insect Probe - Similar to MT-29/1 but sensor
is welded into tip for max. heat transfer. Designed for high accuracy
on extremely small specimens such as insects, seeds, etc. Max.
insertion depth 1/8". Time constant 0.015 secs. 5 ft. lead. Max.
Temp. 150°C. Other sizes made to special order. Not Isolated.
All above probes are non-isolated. Isolated versions of 23 ga.
and larger needles are available for special order.
|
|
| |
Flexible Implantable Probes
|
|
Type |
Dia. |
Time
Constant |
Lead Length |
| IT-14 |
.050" |
0.3 secs. |
3 ft. |
| IT-18 |
.025" |
0.1 secs. |
3 ft. |
| IT-21 |
.016" |
0.08 secs. |
1 ft. |
|
|
IT Series.
Implantable in semi-solids and tissue with needle (supplied). Also for immersion
in various solutions and rectal temperatures of small animals. Totally sheathed
in chemical resistant Teflon. Quite rugged. Max Temp. 150°C. Isolated. Type
# designates needle gauge. (Or one gauge smaller in thin wall).
IT-23 - For ultra fast measurements and for use on micro-size specimens.
Sensor lead only 0.009" dia. Tissue implantable with 23ga. needle (supplied).
Rather fragile. Max. temp. 150°C. Time constant 0.005 secs. 3 ft. lead.
Teflon coated. Isolated.
IT-1E - As IT-18 but sensor bead exposed. Combines the ultra-fast
response of IT-23 with the Teflon sheath strength of IT-18. Time constant
.005 secs. Isolated. |
|
General Purpose Probes |
| DPT-12 12" shaft |
TFT-12 12" shaft |
| DPT-24 24" shaft |
TFT-24 24" shaft |
| DPT-35 36" shaft |
TFT-36 36" shaft |
|
|
|
HT-1
- "Workhorse" probe for liquids, gases, semi-solids. Plastic handle with
straight stainless steel shaft. Not good for surface temps. Max. Temp.
400°C. Time constant 0.5 secs. 5 ft. lead. Not Isolated.
HT-2 - As HT-1 but with 9" shaft.
BT-1 - For surface temperatures of solids, also for liquids, gases
and semi-solids. Probably our best general purpose probe. Welded stainless
steel shaft, plastic handle. Tip is .02" diameter bent at right angle
to probe to facilitate accurate surface measurement. 5 ft. lead. Immersible.
Max. Tip Temp. 240°C. Time constant 0.15 secs. Not Isolated.
DPT Series- Immersion probes for liquids. #304 stainless steel
welded shaft, wooden handle. 5 ft. lead. Max. Temp. 400°C (750°F). Time
constant 2 secs. Not Isolated.
TFT Series - Immersion probes for
corrosive liquids. Similar to DPT series but shaft is Teflon coated. Max.
Temp. 150°C (300°F). Time constant 3 secs. Isolated. 5 ft. lead.
PT-6 - Sensor Six-Pack. For multi-point measurements. Inexpensive,
flexible, welded sensor beads, tough Kapton insulation, 5 ft. leads. Max.
Temp. 400° C. Time constant 0.01 secs. Per package of six. Not Isolated.
PIT-12 - For permanent installation. 12" lnconel shaft 1/8" dia.
Can be formed to fit inside or outside any dia. pipe. Complete with 1/8"
NPT compression fitting. 10 ft. leads and quick-disconnect plugs and sockets.
Max. Temp. 400°C (750° F). Time constant 3 secs. Not Isolated.
PIT-6 - Has 6" stainless steel shaft; otherwise as PIT-12.
GT-1 - Air and gas probe. 24" #304 stainless steel shaft, wooden
handle. 5 ft. leads. For instant readings of temperature gradients in
environmental chambers, freezer boxes, etc. Max. Temp. 200°C. Min. Temp.
-200°C. Isolated. |
|
Clinical Probes
|
|
|
RET-1 - Rectal probe for humans, neonatal, rabbits, and larger
animals. Flexible, vinyl covered, soft tipped. Does not cause discomfort.
Max. Temp. 90°C. Time constant 5.0 secs. 5 ft. lead. Isolated.
OT-1 - For fast reading oral use. Ball-tipped stainless steel shaft,
stainless handle. 5 ft. lead. Max. Temp. 125°C. Time constant 0.8 secs.
Not Isolated.
DSP-1 - Disposable sheaths for use with OT-1 and RET-1, per 1000.
SST-1 - Skin surface probe, to be taped on. 1/4" dia. 10 Kt. gold
sensor disc, 5 ft. lead. Max. Temp. 90°C. Time constant 0.15 secs. Not Isolated.
SST-2 - as SST-1 with plastic handle. Isolated.
ESO-1 - Esophageal probe. Flexible vinyl covered 1/8" dia. Max. Temp.
90° C. Time constant 5.0 secs. 5 ft. lead. Isolated. |
|
Animal Rectal Probes
|
|
|
RET-2 - Rectal probe for rats. For fast intermittent measurements.
Smooth ball tip. Stainless steel shaft - 1 " long, 0.59" dia., tip dia.
.125". 5 ft. lead. Max Temp. 125°C. Time constant 0.8 secs. Not Isolated.
RET-3 - Rectal probe for mice, etc. As RET-2, with shaft 3/4" long.
.028" dia. Tip diameter .065". Time constant 0.5 secs. Not Isolated.
|
|
Multi-Sensor Temperature Probes
These sensors are made with our specially manufactured thermocouple wire.
We testand grade thiswire to standards better than the accepted "Special
Limits of Error" and guarantee 0.1°C accuracy in the range of 0-50° C.
All multi-sensor probesare custom-made at this time, and should be ordered
to your requirements. Reuseable microprobes are gas sterilizable |
|

IT SERIES FLEXIBLE TEFLON PROBES
|
.Teflon sheathed thermocouple
wires are implanted with regular hypodermic needle. 14ga. or 17g
When ordering, specify: Probe series (IT), needle gauge, number sensors
and distance between sensors.
(e.g.: IT-17(3) is implanted with 17 ga needle and has 3 sensors. Unless
otherwise specified we put sensors 1cm apart, starting at tip.) |
|

MT Series Needle Microprobes
|
|
These stainless steel microprobes
have closed, sharpened tips. We can put up to 3 sensors in a 23ga needle
and 1 or 2 sensors in a 26ga needle.
When ordering, specify: Probe series (MT),
needle gauge, needle length, number of sensors and distance between sensors
in cm.
e.g. MT-23/5(2) is a 23ga needle, 5 cm needle, 5cm long with 2sensors.
Unlessotherwisespecified sensorswill be lcm apart, starting at tip.
We also manufacture interchangeable single sensor probes and microprobes
available in many configurations. Our thermocouple probes include clinical
probes-skin, rectal, oral and esophageal. There are implantable needle
and flexible sensors and probes for measuring surfaces, liquid and air.
See our data sheet on interchangeable probes and sensors for more descriptive
information on individual probes. |
|
| |
Copyright (c) 2005.
IITC Life Science
All rights reserved. |
|
|