Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals
The IITC Life Science tail cuff plethysmography blood pressure systems can be configured from 1-24 animals.
The IITC Rotarod Test is used to assess the effect of drugs on the motor coordination or fatigue resistance on mice and rats using one unit in a safe and humane way. The animals are placed on textured drums to avoid slipping. When an animal drops onto the individual sensing platforms below, test results are recorded digitally and displayed on the front panel.
The IITC Animal Treadmills for mice and rats is a general purpose exerciser that can be ordered up to five (5) lanes. Our unit is designed to enable the operator a more precise reading in conjunction with the amount of exercise given to the animal. This digitally controlled unit has a high degree of repeatability.
The GEMINI Respiration Monitor measures CO2, O2, and respiration rate of spontaneously breathing or ventilated animals. It provides breath-by-breath readings for end-tidal CO2 and O2, and instantaneous respiratory rate (breaths/minute). Adjustable alarms are provided to monitor CO2 and respiratory rate.
Create custom blends from any three gasses
The GSM-3 Programmable Gas Mixture takes up to three input gasses and produces user-defined mixtures using these gasses. Up to four different mix programs can be defined and stored at any one time. These mixtures are stored in non-volatile memory, so they don’t have to be re-entered the next time the instrument is used. The GSM-3 uses high-accuracy mass flow controllers (MFC’s) to set the flow for each gas channel.
The IITC Incapacitance Test Meter is used for test assessment of pain and or inflammation of the hind limbs on mice and rats. It overcomes the drawbacks of other methods that might cause unnececessary stress or subjectivity on the animal. The technique known as dynamic weight bearing enables the test on both limbs allowing a clean stress free correlation to the paw pressure test. Control and testing can be done on the same animal at the same time.
Part No. 10-02010
SUPER-Z Head-Stage
Very high-impedance head-stage for use with all CWE amplifiers, including BMA-200, BMA-400, and BMA-931. Features switchable 1X/10X gain, AC or DC coupling, DC microvolt calibrator, and adjustable DC offset. Inputs are 0.080″ (2mm) pin jacks. Flip-up feet (shown extended).
Dimensions: 3.5″W x 4″D x 1″H (8.9 x 10.1 x 2.5cm)
Touch pressure threshold testing involves the use of nylon monofilaments of
different lengths and increasing diameters. These monofilaments provide controlled
gradients of force to the mechanoreceptors in the skin and can thus be used to
determine pressure detection thresholds. The advantage of monofilament testing is
that it provides quantified and repeatable information about a patient’s detection of
touch. The pattern of sensibility loss reflected by the monofilament testing helps to
identify pathology.
IITC Life Science has developed the first commercially available unit that has the capability of performing four individual tests with one unit.
Availability: 30 in stock
The IITC Rodent Pincher allows researchers to measure and test pain threshold in a simple, accurate method when measuring pain nociception.
IITC’s Paw Volume Meter enables researchers to measure the effectiveness of anti-inflammatory agents and agents to reduce edemic conditions. In use, the paw is inserted into plain water, which contains a special water cell of which the pressure is changed due to the immersion. This pressure change is calibrated in ml and shown on a special electronic monitor. This form of detection eliminates changes due to conductivity alterations at repeated insertions as found on comparable units.
IITC Life Science has developed the first commercially available unit that has the capability of performing four individual tests with one unit.
Order any one of the test systems complete and the only additional item(s) needed are the individual modules to perform each test.
IITC Life Science Grip Strength Test for rat and mouse is used to to assess muscle hyperalgesia. The IITC Life Science instrument measures the forelimb grip force using a digital force transducer.
IITC Mesh Stands are ideal for large group studies. When studies call for rapid screening of pain and sensory thresholds when using in conjunction the IITC Life Science Electronic von Frey the IITC mesh stands are a wonderful addition to any research laboratory.